  series am 30kw -iz 30 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12 1 of 5 north a merica only features: ? ultra - wide 4:1 input ? standard package 2x1.6 ? continuous short circuit protection ? high efficiency up to 85 % ? remote on/off control ? rohs compliant models single output model input voltage (v) output voltage (v) output current max ( a) is olation (vdc) efficiency (%) am30kw - 2403siz 9 - 36 3.3 5.4 1500 78 am30kw - 2405siz 9 - 36 5 6 1500 81 am30kw - 2412siz 9 - 36 12 2.5 1500 84 am30kw - 2415siz 9 - 36 15 2 1500 82 am30kw - 2424siz 9 - 36 24 1.25 1500 82 am30kw - 4803siz 18 - 75 3.3 5.4 1500 78 am30kw - 480 5siz 18 - 75 5 6 1500 80 am30kw - 4812siz 18 - 75 12 2.5 1500 83 am30kw - 4815siz 18 - 75 15 2 1500 83 am30kw - 4824siz 18 - 75 24 1.25 1500 83 am30kw - 2403sh30iz 9 -36 3.3 5.4 3000 78 am30kw - 2405sh30iz 9 - 36 5 6 3000 81 am30kw - 2412sh30iz 9 - 36 12 2.5 3000 84 am30kw - 2415sh30iz 9 - 36 15 2 3000 82 am30kw - 2424sh30iz 9 - 36 24 1.25 3000 82 am30kw - 4803sh30iz 18 - 75 3.3 5.4 3000 78 am30kw - 4805sh30iz 18 - 75 5 6 3000 80 am30kw - 4812sh30iz 18 - 75 12 2.5 3000 83 am30kw - 4815sh30iz 18 - 75 15 2 3000 83 am30kw - 4824sh30iz 18 - 75 24 1.25 3000 83 models dual output model input voltage (v) output voltage (v) output current max (ma) isolation (vdc) efficiency (%) am30kw - 2405diz 9 - 36 5 3 1500 81 am30kw - 2412diz 9 - 36 12 1.25 1500 82 am30kw - 2415diz 9 - 36 15 1 1500 83 am30kw - 4805diz 18 - 75 5 3 1500 83 am30kw - 4812diz 18 - 75 12 1.25 1500 85 am30kw - 4815diz 18 - 75 15 1 1500 85 am30kw - 2405dh30iz 9 - 36 5 3 3000 81 am30kw - 2412dh30iz 9 - 36 12 1.25 3000 82 am30kw - 2415dh30iz 9 - 36 15 1 3000 83 am30kw - 4805dh30iz 18 - 75 5 3 3000 83 am30kw - 4812dh30iz 18 - 75 12 1.25 3000 85 am30kw - 4815dh30iz 18 - 75 15 1 3000 85 note: all specifications in this datasheet are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unles s otherwise specified.
series am 30kw -iz 30 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12 2 of 5 north a merica only input specifications parameters nominal typical maximum units voltage range 24 9 -36 vdc 48 18 - 75 filter (pi) network start up time ms recommended input fuse (slow blow) 24 4a/250v 48 2a/250v absolute maximum rating 24 50 vdc 48 100 peak input voltage time ms on/off c ontrol on C ttl high or open ; off C ttl low or short no load input curr ent ma isolation specifications parameters conditions typical maximum units tested i/o voltage 3 sec 1500 & 3000 vdc resistance 500vdc >1000 mohm output specifications parameters conditions typical maximum units voltage accuracy 2 % over voltage protection zener diode clamp over current protection >110 % short circuit protection continuous short circuit restart auto recovery line voltage regulat ion hl - ll 0.5 % of vin load voltage regulation (single) 25 - 100% 0.5 % load voltage r egulation (dual) 25 - 100% 1 % temperature coefficient 0.05 %/ o c ripple & noise 20mhz bandwidth 150 mv p - p voltage adjustment range 10 % minimum load current 25 % of max general specifications parameters conditions typical maximum units swi tching frequency 100 % load 250 khz operating temperature with derating above 70oc - 40 to +85 o c storage temperature - 55 to +105 o c maximum case temperature 100 o c cooling free air convection humidity 95 % rh case material nickel coated copper w ith non - conductive base weight 50 g dimensions (l x w x h) 2.00 x 1.60 x 0.40 inches 50.80 x 40.60 x 10. 20 mm mtbf > 550 000 hrs (mil - hdbk - 217f, ground benign, t=+25 o c) maximum s oldering t emperature o c transient r ecovery time 25% step change 2 80 u s transient recovery deviation ms safety specifications parameters agency approvals ce standards en 55022, en 55024 class a
series am 30kw -iz 30 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12 3 of 5 north a merica only pin out specifications dimensions pin single dual 1 +v input +v input 2 - v input - v input 3 on/off control on/off control 4 no pin +v output 5 +v output common 6 - v output - v output 7 trim trim 1 5 . 0 8 (0 . 2 0 ) 7 . 6 2 ( 0 . 3 0 ) 1 7 . 7 8 (0 . 7 0 ) 5 . 1 0 (0 . 2 0 ) 5 . 1 0 (0 . 2 0 ) 2 3 4 5 6 7 1 0 . 1 6 (0 . 4 0 ) 1 0 . 1 6 (0 . 4 0 ) 1 0 . 1 6 (0 . 4 0 ) 1 0 . 1 6 (0 . 4 0 ) bottom view 50. 80 (2 . 00 ) 4 0 . 6 0 (1 . 6 0 ) 1 0 . 1 6 (0 . 4 0 ) ? 1 . 00 (0 . 04 ) printed face 2 . 54 (0 . 10) 5 . 6 0 (0 . 2 2 ) 45. 72 ( 1 . 80 ) case tolerance 0 . 50 ( 0 . 02) pin pitch tolerance 0 . 35 ( 0 . 014 ) dimensions mm ( inch )
series am 30kw -iz 30 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12 4 of 5 north a merica only trimming derating 1500vdc isolation 3000vdc isolation - 40 - 20 0 20 40 60 80 100 100 80 60 40 20 0 safe operating area o u t p u t po w e r (% ) 85 ambient temperature o c a b c d b 100 lfm a free air 70 o c 75 o c c 200 lfm 80 o c d 400 lfm 85 o c - 40 - 20 0 20 40 60 80 100 100 80 60 40 20 0 safe operating area output power (%) 85 ambient temperature o c free air convection 40 o c
series am 30kw -iz 30 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12 5 of 5 north a merica only contro l on/off pin connection example single output dual output digital control circuit: control voltage on / off control -v input 0.5ma dc/dc converter npn 0v vpeak ra = vpeak C 0.6 0.5ma note: 1. datasheets are updated as needed and as such, specifications are subject to change without notice. once printed or downloaded, datasheets are no longer controlled by aimtec; refer to www.aimtec.com for the most current product specifications. 2. product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. mechanical drawings and specifications are for reference only. 4 . all s pecifications are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specifie d. 5. aimtec may not hav e conducted destructive testing or chemical analysis on all internal components and c hemicals at the time of publishing this document. cas numbers and other limited information are considered proprietary and may not be available for release. 6. this product is not designed for use in critical life support systems, equipment used in hazar dous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet . 7. warranty is in accordance with aimtecs standard terms of sale available at www.aimtec.com .


▲Up To Search▲   

 
Price & Availability of AM30KW-2412DH30IZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X